CVE-2024-52569
Siemens Tecnomatix Plant Simulation vulnerability analysis and mitigation

Overview

CVE-2024-52569 is an out-of-bounds write vulnerability affecting multiple versions of Siemens Teamcenter Visualization and Tecnomatix Plant Simulation software. The vulnerability was discovered and reported through the Zero Day Initiative (ZDI-CAN-24260) and was publicly disclosed on November 18, 2024. The affected versions include Teamcenter Visualization V14.2 (versions < V14.2.0.14), V14.3 (versions < V14.3.0.12), V2312 (versions < V2312.0008), V2406 (versions < V2406.0005), and Tecnomatix Plant Simulation V2302 (versions < V2302.0018) and V2404 (versions < V2404.0007) (Siemens Advisory, ZDI Advisory).

Technical details

The vulnerability is classified as an out-of-bounds write (CWE-787) that occurs when parsing specially crafted WRL files. It has been assigned a CVSS v3.1 base score of 7.8 (HIGH) with the vector string CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, and a CVSS v4.0 base score of 7.3 with the vector string CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N. The vulnerability requires local access and user interaction to exploit (Siemens Advisory).

Impact

If successfully exploited, this vulnerability could allow an attacker to execute arbitrary code in the context of the current process. The impact affects the confidentiality, integrity, and availability of the system with high severity levels (Siemens Advisory, ZDI Advisory).

Mitigation and workarounds

Siemens has released security updates to address this vulnerability and recommends updating to the following versions: Teamcenter Visualization V14.2.0.14 or later, V14.3.0.12 or later, V2312.0008 or later, V2406.0005 or later, and Tecnomatix Plant Simulation V2302.0018 or later, V2404.0007 or later. As a workaround, users are advised not to open untrusted WRL files in affected applications. Additionally, Siemens recommends protecting network access to devices with appropriate mechanisms and following their operational guidelines for industrial security (Siemens Advisory).

Additional resources


SourceThis report was generated using AI

Related Siemens Tecnomatix Plant Simulation vulnerabilities:

CVE ID

Severity

Score

Technologies

Component name

CISA KEV exploit

Has fix

Published date

CVE-2025-40801CRITICAL9.2
  • Siemens Tecnomatix Plant SimulationSiemens Tecnomatix Plant Simulation
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation
NoYesDec 09, 2025
CVE-2025-32454HIGH7.3
  • Siemens Tecnomatix Plant SimulationSiemens Tecnomatix Plant Simulation
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation
NoYesMay 13, 2025
CVE-2025-27438HIGH7.3
  • Siemens Tecnomatix Plant SimulationSiemens Tecnomatix Plant Simulation
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation
NoYesMar 11, 2025
CVE-2025-25266HIGH7
  • Siemens Tecnomatix Plant SimulationSiemens Tecnomatix Plant Simulation
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation
NoYesMar 11, 2025
CVE-2025-25267MEDIUM6.9
  • Siemens Tecnomatix Plant SimulationSiemens Tecnomatix Plant Simulation
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation
NoYesMar 11, 2025

Free Vulnerability Assessment

Benchmark your Cloud Security Posture

Evaluate your cloud security practices across 9 security domains to benchmark your risk level and identify gaps in your defenses.

Request assessment

Get a personalized demo

Ready to see Wiz in action?

"Best User Experience I have ever seen, provides full visibility to cloud workloads."
David EstlickCISO
"Wiz provides a single pane of glass to see what is going on in our cloud environments."
Adam FletcherChief Security Officer
"We know that if Wiz identifies something as critical, it actually is."
Greg PoniatowskiHead of Threat and Vulnerability Management