Cloud Vulnerability DB
A community-led vulnerabilities database
CVE-2026-23719 is a heap-based buffer overflow vulnerability affecting Siemens Simcenter Femap and Simcenter Nastran, both in all versions prior to V2512. The flaw is triggered when the affected applications parse specially crafted NDB files, potentially allowing an attacker to execute arbitrary code in the context of the current process. The vulnerability was published on February 10, 2026, with a patch advisory released by Siemens on February 11, 2026. It carries a CVSS v3.1 base score of 7.3 (High) (Siemens CERT, Red Hat CVE).
The root cause is classified as CWE-122 (Heap-based Buffer Overflow), occurring during the parsing of NDB file formats within Simcenter Femap and Simcenter Nastran. An attacker must supply a specially crafted NDB file that, when opened by a user with low privileges, causes the application to write beyond the bounds of a heap-allocated buffer. Exploitation requires local file access and user interaction (i.e., a victim must open the malicious file), but does not require elevated privileges. No public proof-of-concept or technical write-up detailing the specific parsing flaw has been identified at this time (Siemens CERT, CISA ICS Advisory).
Successful exploitation allows an attacker to execute arbitrary code with the privileges of the user running the affected application, resulting in high impact to confidentiality, integrity, and availability of the compromised system. An attacker could steal sensitive engineering or simulation data, modify files, or disrupt application operations. The scope is limited to the affected process and local system, with no direct impact on adjacent systems unless the compromised account has broader network access (Siemens CERT, Red Hat CVE).
cmd.exe, powershell.exe, sh, curl); application crashes or unexpected termination after opening an NDB file.Siemens has released version V2512 for both Simcenter Femap and Simcenter Nastran, which resolves this vulnerability. Users should upgrade to V2512 or later as the primary remediation. Until patching is complete, organizations should restrict user access to untrusted NDB files, educate users to avoid opening NDB files from unknown or untrusted sources, and consider implementing file integrity monitoring on directories used by these applications (Siemens CERT, CISA ICS Advisory).
CISA published an ICS advisory (ICSA-26-048-01) highlighting the vulnerability for industrial control system operators. Security news outlets including IT Security News and Red Packet Security covered the disclosure, and the vulnerability was noted on VulDB and Infosec Exchange. No significant researcher commentary or notable social media debate has been identified beyond routine vulnerability tracking (CISA ICS Advisory, IT Security News).
Source: This report was generated using AI
Free Vulnerability Assessment
Evaluate your cloud security practices across 9 security domains to benchmark your risk level and identify gaps in your defenses.
Get a personalized demo
"Best User Experience I have ever seen, provides full visibility to cloud workloads."
"Wiz provides a single pane of glass to see what is going on in our cloud environments."
"We know that if Wiz identifies something as critical, it actually is."