CVE-2025-29931
Telecontrol Server Basic vulnerability analysis and mitigation

Overview

A vulnerability (CVE-2025-29931) has been identified in TeleControl Server Basic (versions prior to V3.1.2.2). The vulnerability relates to improper validation of length fields in serialized messages, which affects memory allocation during deserialization. This vulnerability was discovered by Jin Huang from ADLab of Venustech and was disclosed on April 17, 2025 (Siemens Advisory).

Technical details

The vulnerability stems from improper handling of length parameter inconsistency (CWE-130) in the TeleControl Server Basic system. When processing serialized messages, the application fails to properly validate length fields used for memory allocation during deserialization. The vulnerability has received a CVSS v3.1 base score of 3.7 (LOW) with vector string CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L, and a CVSS v4.0 score of 6.3 (MEDIUM) with vector string CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N (CISA Advisory).

Impact

If successfully exploited, this vulnerability could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory, resulting in a partial denial-of-service (DoS) condition. The impact is limited to redundant TeleControl Server Basic setups and only occurs when the connection between redundant servers has been disrupted (Siemens Advisory).

Mitigation and workarounds

Siemens has released version V3.1.2.2 to address this vulnerability and recommends updating to this or a later version. As a workaround, organizations can disable TeleControl Server Basic redundancy if not in use. Additionally, Siemens recommends protecting network access to devices with appropriate mechanisms and configuring the environment according to Siemens' operational guidelines for Industrial Security (Siemens Advisory).

Community reactions

The vulnerability has gained attention in the industrial control systems security community, with CISA releasing an advisory as part of a broader set of ICS vulnerability announcements. The relatively low severity score and specific exploitation conditions have resulted in measured concern from the security community (Cybersecurity News).

Additional resources


SourceThis report was generated using AI

Related Telecontrol Server Basic vulnerabilities:

CVE ID

Severity

Score

Technologies

Component name

CISA KEV exploit

Has fix

Published date

CVE-2025-40765CRITICAL9.3
  • Telecontrol Server BasicTelecontrol Server Basic
  • cpe:2.3:a:siemens:telecontrol_server_basic
NoNoOct 14, 2025
CVE-2025-32872HIGH8.7
  • Telecontrol Server BasicTelecontrol Server Basic
  • cpe:2.3:a:siemens:telecontrol_server_basic
NoYesApr 16, 2025
CVE-2025-32871HIGH8.7
  • Telecontrol Server BasicTelecontrol Server Basic
  • cpe:2.3:a:siemens:telecontrol_server_basic
NoYesApr 16, 2025
CVE-2025-30033HIGH8.5
  • Telecontrol Server BasicTelecontrol Server Basic
  • cpe:2.3:a:siemens:telecontrol_server_basic
NoYesAug 12, 2025
CVE-2025-29931MEDIUM6.3
  • Telecontrol Server BasicTelecontrol Server Basic
  • cpe:2.3:a:siemens:telecontrol_server_basic
NoYesApr 17, 2025

Free Vulnerability Assessment

Benchmark your Cloud Security Posture

Evaluate your cloud security practices across 9 security domains to benchmark your risk level and identify gaps in your defenses.

Request assessment

Get a personalized demo

Ready to see Wiz in action?

"Best User Experience I have ever seen, provides full visibility to cloud workloads."
David EstlickCISO
"Wiz provides a single pane of glass to see what is going on in our cloud environments."
Adam FletcherChief Security Officer
"We know that if Wiz identifies something as critical, it actually is."
Greg PoniatowskiHead of Threat and Vulnerability Management